The big idea
Interval recording and time sampling turn behavior into a series of yes-or-no decisions. The observer divides a session into equal intervals, scores each one by a rule, and reports the percentage of intervals scored.
That percentage is an estimate, and each rule distorts it in a predictable direction. If you know the direction, you can pick the method that fits the behavior and errs on the side you can accept.
Breaking it down
Whole-interval recording
Whole-interval recording scores an interval only if the behavior occurs throughout the entire interval. Any break, however short, means the interval is not scored.
- It tends to underestimate the behavior.
- It fits continuous behaviors you want to increase, such as on-task behavior or cooperative play. Because it understates the behavior, any improvement it shows is conservative.
Partial-interval recording
Partial-interval recording scores an interval if the behavior occurs at any point during it, even for one second. Once the interval is scored, the observer can stop watching until the next one begins.
- It tends to overestimate the share of time the behavior occupies. It also undercounts frequent behavior, because five responses in one interval score the same as one.
- It fits behaviors you want to decrease, since overestimating makes improvement look smaller, not larger. It also suits brief behaviors that start and stop too quickly to count.
Momentary time sampling (MTS)
Momentary time sampling scores an interval only if the behavior is occurring at the moment the interval ends. Whatever happens between those moments is ignored.
- It can overestimate or underestimate; the error does not run in one direction.
- With short intervals, it gives a good estimate of the share of time taken up by behaviors that last a while, such as engagement or in-seat behavior.
- It misses brief or infrequent behavior.
- It suits observers who can only glance up now and then, such as a teacher running a lesson.
Planned activity check (PLACHECK)
A planned activity check is a group version of MTS. At each scheduled moment, the observer counts how many people in a group are doing the target behavior and divides by the number present. If 9 of 12 children are engaged with materials at 10:15, the score for that check is 75%.
Designing the procedure
- Choose the method from the behavior’s form and the direction of error you can accept.
- Choose the interval length. Shorter intervals give closer estimates with all three methods but are harder to score. For partial-interval recording, an interval shorter than the usual gap between responses means each interval rarely holds more than one response, so the percentage tracks the count more closely. Research intervals are often about 10 seconds; classroom MTS often uses intervals of one to several minutes.
- Decide on recording time. Some systems alternate observing and recording (for example, observe 10 seconds, record 5). Behavior during recording time is not observed.
- Use a cue, such as an audio signal or a vibrating timer, so observers stay in step.
- Report the percentage of intervals: scored intervals ÷ total intervals × 100. A 15-minute session in 15-second intervals has 60 intervals, and behavior scored in 21 of them is 21 ÷ 60 = 35%.
Seeing it in practice
Carlos’s out-of-seat behavior is scored three ways across five 10-second intervals.
| Interval | What happened | Whole | Partial | Momentary |
|---|---|---|---|---|
| 1 (0-10 s) | Out of seat the whole time | Yes | Yes | Yes |
| 2 (10-20 s) | Out of seat until 14 s | No | Yes | No |
| 3 (20-30 s) | Seated throughout | No | No | No |
| 4 (30-40 s) | Out of seat from 33 to 37 s | No | Yes | No |
| 5 (40-50 s) | Out of seat from 45 s onward | No | Yes | Yes |
| Result | Actually out of seat 23 of 50 s (46%) | 20% | 80% | 40% |
Whole-interval recording came in far below the true value and partial-interval recording far above it. Momentary time sampling came closest here, but with different timing it could have missed in either direction.
Common mix-ups
- Getting the direction of error backwards. Whole underestimates, partial overestimates, MTS can go either way.
- Reporting intervals as occurrences. “Scored in 12 intervals” is not “occurred 12 times.”
- Pairing method and goal backwards. The conservative pairing is whole-interval for behavior to increase and partial-interval for behavior to decrease.
- Intervals that are too long. With 5-minute partial intervals, one 2-second hit scores the whole 5 minutes, and the data can sit at 100% in every phase.
- Confusing PLACHECK with MTS. Both sample a moment; PLACHECK scores a group, MTS scores one person.
Exam tip: Sketch a quick timeline, mark when the behavior happened, and apply the rule to each interval: the whole interval, any part of it, or the final moment. The arithmetic shows which way each method misses.
Quick recap
- Whole-interval: the behavior must fill the interval; underestimates; conservative for behavior to increase.
- Partial-interval: any occurrence counts; overestimates; conservative for behavior to decrease.
- Momentary time sampling: only the final moment counts; errs either way; good for long-lasting behavior when intervals are short.
- PLACHECK is momentary time sampling for a group.
- Shorter intervals give better estimates. Report data as a percentage of intervals.
Further reading
- Cooper, J. O., Heron, T. E., & Heward, W. L. (2020). Applied behavior analysis (3rd ed.), chapter 4.
Key terms
- Interval recording
- A discontinuous procedure that divides an observation period into equal intervals and scores each interval for whether the behavior occurred, under a whole-interval or partial-interval rule. Data are reported as the percentage of intervals scored. Some texts group it with momentary methods under the broader label time sampling.
- Whole-interval recording
- Interval recording in which an interval is scored only if the behavior occurs throughout the entire interval. It tends to underestimate the behavior, which makes it a conservative measure for behaviors a team wants to increase.
- Partial-interval recording
- Interval recording in which an interval is scored if the behavior occurs at any point during it. It tends to overestimate how much of the time the behavior takes up and undercounts frequent behavior, which makes it a conservative measure for behaviors a team wants to decrease.
- Momentary time sampling (MTS)
- Recording whether the behavior is occurring at the precise moment each interval ends, ignoring what happens in between. It can overestimate or underestimate, and with short intervals it gives a good estimate of the share of time taken up by long-lasting behaviors. It tends to miss brief or rare behavior.
- Planned activity check (PLACHECK)
- A group form of momentary time sampling. At each scheduled moment, the observer counts how many people in a group are doing the target behavior and divides by the number present.
Check yourself
4 questions on C.6. Choose an answer to see whether you're right and why.
Show the answer
Answer: C. Whole-interval recording scores an interval only when the behavior fills all of it, so any brief break, even a two-second glance away, loses the whole interval. That makes it tend to underestimate. Overestimation is the typical error of partial-interval recording.
Show the answer
Answer: B. Partial-interval recording scores any burst and tends to overestimate, so a reduction it shows is unlikely to be exaggerated. Whole-interval recording would rarely score brief bursts at all and would make the behavior look lower than it is, which overstates improvement. A planned activity check measures a group, not one learner.
Show the answer
Answer: C. Each check is a percentage of the group: 15 ÷ 20 = 75%, 12 ÷ 20 = 60% and 18 ÷ 20 = 90%. The mean is (75 + 60 + 90) ÷ 3 = 75%, the same as 45 engaged out of 60 student observations. The 60% and 90% figures are single checks, and 45 is a count of students, not a percentage.
Show the answer
Answer: A. With long intervals, a single call-out scores a full 2 minutes, so the data sit at 100% and cannot show change, which is a measurement artifact. Shorter intervals, or simply counting call-outs, let the data reflect the reduction. Whole-interval recording would almost never score a brief call-out, and longer intervals would make the ceiling problem worse.
Adds a step to your study record. Saved in this browser only.